assign_2way_coupling#
- Icepak.assign_2way_coupling(setup=None, number_of_iterations=2, continue_ipk_iterations=True, ipk_iterations_per_coupling=20)#
Assign two-way coupling to a setup.
- Parameters:
- setup
str
,optional
Name of the setup. The default is
None
, in which case the active setup is used.- number_of_iterations
int
,optional
Number of iterations. The default is
2
.- continue_ipk_iterationsbool,
optional
Whether to continue Icepak iterations. The default is
True
.- ipk_iterations_per_coupling
int
,optional
Additional iterations per coupling. The default is
20
.
- setup
- Returns:
- bool
True
when successful,False
when failed.
References
>>> oModule.AddTwoWayCoupling
Examples
>>> icepak.assign_2way_coupling("Setup1",1,True,10) True