create_fieldplot_nets#
- PostProcessor3DLayout.create_fieldplot_nets(nets: list, quantity: str, setup: str = None, layers: list = None, plot_on_surface: bool = True, intrinsics: dict = None, name: str = None) FieldPlot #
Create a field plot of stacked layer plot based on a net selections. Layers can be used as a filter. Dielectrics will be excluded from the plot. This plot is valid from AEDT 2023 R2 and later in HFSS 3D Layout. It works when a layout components in 3d modeler is used.
- Parameters:
- nets
list
,optional
List of nets to filter the field plot.
- quantity
str
Name of the quantity to plot.
- setup
str
,optional
Name of the setup. The default is
None
, in which case thenominal_adaptive
setup is used. Make sure to build a setup string in the form of"SetupName : SetupSweep"
, whereSetupSweep
is the sweep name to use in the export orLastAdaptive
.- layers
list
,optional
List of layers to plot. For example:
["Layer1","Layer2"]
. If empty list is provided all layers are considered.- intrinsics
dict
,str
,optional
Intrinsic variables required to compute the field before the export. These are typically: frequency, time and phase. It can be provided either as a dictionary or as a string. If it is a dictionary, keys depend on the solution type and can be expressed in lower or camel case as:
"Freq"
or"Frequency"
."Time"
."Phase"
.
If it is a string, it can either be
"Freq"
or"Time"
depending on the solution type. The default isNone
in which case the intrinsics value is automatically computed based on the setup.- plot_on_surfacebool,
optional
Whether if the plot has to be on surfaces or inside the objects. It is applicable only to layout components. Default is
True
.- name
str
,optional
Name of the field plot to create.
- nets
- Returns:
- :class:
ansys.aedt.core.modules.solutions.FieldPlot
or bool Plot object.
- :class:
References
>>> oModule.CreateFieldPlot