RMXprt templates and arguments#

This section lists all setup templates with their default values and keys available in RMXprt.

You can edit a setup after it is created. Here is an example:

from ansys.aedt.core import Hfss

hfss = Hfss()
# Any property of this setup can be found on this page.
setup = hfss.create_setup()
setup.props["AdaptMultipleFreqs"] = True
setup.update()
GRM
{ 'CapacitivePowerFactor': False,
  'Enabled': True,
  'Frequency': '60Hz',
  'LoadType': 'ConstPower',
  'OperatingTemperature': '75cel',
  'OperationType': 'Motor',
  'RatedOutputPower': '1kW',
  'RatedPowerFactor': '0.8',
  'RatedSpeed': '1000rpm',
  'RatedVoltage': '100V'}
DFIG
{ 'CapacitivePowerFactor': False,
  'Enabled': True,
  'Frequency': '60Hz',
  'LoadType': 'InfiniteBus',
  'OperatingTemperature': '75cel',
  'OperationType': 'Wind Generator',
  'RatedOutputPower': '1kW',
  'RatedPowerFactor': '0.8',
  'RatedSpeed': '1000rpm',
  'RatedVoltage': '100V'}
TPIM
{ 'Enabled': True,
  'Frequency': '60Hz',
  'LoadType': 'ConstPower',
  'OperatingTemperature': '75cel',
  'OperationType': 'Motor',
  'RatedOutputPower': '1kW',
  'RatedSpeed': '1000rpm',
  'RatedVoltage': '100V',
  'WindingConnection': 0}
TPSM
{ 'Enabled': True,
  'ExciterEfficiency': 90,
  'ExcitingCurrent': '0A',
  'InputExcitingCurrent': False,
  'LoadType': 'InfiniteBus',
  'OperatingTemperature': '75cel',
  'OperationType': 'Generator',
  'RatedOutputPower': '100',
  'RatedPowerFactor': 0.8,
  'RatedSpeed': '1000rpm',
  'RatedVoltage': '100V',
  'StartingFieldResistance': '0ohm',
  'WindingConnection': False}
BLDC
{ 'Enabled': True,
  'LoadType': 'ConstPower',
  'OperatingTemperature': '75cel',
  'OperationType': 'Motor',
  'RatedOutputPower': '1kW',
  'RatedSpeed': '1000rpm',
  'RatedVoltage': '100V'}
ASSM
{ 'Enabled': True,
  'LoadType': 'ConstPower',
  'OperatingTemperature': '75cel',
  'OperationType': 'Motor',
  'RatedOutputPower': '1kW',
  'RatedSpeed': '1000rpm',
  'RatedVoltage': '100V'}
PMDC
{ 'Enabled': True,
  'LoadType': 'ConstPower',
  'OperatingTemperature': '75cel',
  'OperationType': 'Motor',
  'RatedOutputPower': '1kW',
  'RatedSpeed': '1000rpm',
  'RatedVoltage': '100V'}
SRM
{ 'Enabled': True,
  'LoadType': 'ConstPower',
  'OperatingTemperature': '75cel',
  'OperationType': 'Motor',
  'RatedOutputPower': '1kW',
  'RatedSpeed': '1000rpm',
  'RatedVoltage': '100V'}
LSSM
{ 'Enabled': True,
  'LoadType': 'ConstPower',
  'OperatingTemperature': '75cel',
  'OperationType': 'Motor',
  'RatedOutputPower': '1kW',
  'RatedSpeed': '1000rpm',
  'RatedVoltage': '100V',
  'WindingConnection': False}
UNIM
{ 'Enabled': True,
  'Frequency': '60Hz',
  'LoadType': 'ConstPower',
  'OperatingTemperature': '75cel',
  'OperationType': 'Motor',
  'RatedOutputPower': '1kW',
  'RatedSpeed': '1000rpm',
  'RatedVoltage': '100V'}
DCM
{ 'DeterminedbyRatedSpeed': False,
  'Enabled': True,
  'ExcitingVoltage': '100V',
  'FieldExcitingType': False,
  'LoadType': 'InfiniteBus',
  'OperatingTemperature': '75cel',
  'OperationType': 'Generator',
  'RatedOutputPower': '1kW',
  'RatedSpeed': '1000rpm',
  'RatedVoltage': '100V',
  'SeriesResistance': '1ohm'}
CPSM
{ 'Enabled': True,
  'ExcitingCurrent': '0A',
  'InputExcitingCurrent': False,
  'LoadType': 'InfiniteBus',
  'OperatingTemperature': '75cel',
  'OperationType': 'Generator',
  'RatedOutputPower': '100',
  'RatedPowerFactor': '0.8',
  'RatedSpeed': '1000rpm',
  'RatedVoltage': '100V'}
NSSM
{ 'Enabled': True,
  'ExciterEfficiency': 90,
  'ExcitingCurrent': '0A',
  'InputExcitingCurrent': False,
  'LoadType': 'InfiniteBus',
  'OperatingTemperature': '75cel',
  'OperationType': 'Generator',
  'RatedOutputPower': '100',
  'RatedPowerFactor': 0.8,
  'RatedSpeed': '1000rpm',
  'RatedVoltage': '100V',
  'StartingFieldResistance': '0ohm',
  'WindingConnection': False}