start_continue_from_previous_setup#
- SetupHFSS.start_continue_from_previous_setup(design, solution, map_variables_by_name=True, parameters=None, project='This Project*', force_source_to_solve=True, preserve_partner_solution=True)#
Start or continue from a previously solved setup.
- Parameters:
- design
str
Name of the design.
- solution
str
Name of the solution in the format
"name : solution_name"
. For example,"Setup1 : Transient", "MySetup : LastAdaptive"
.- map_variables_by_namebool,
optional
Whether variables are mapped by name from the source design. The default is
True
.- parameters
dict
,optional
Dictionary of the parameters. This parameter is not considered if
map_variables_by_name=True
. IfNone
, the default isappname.available_variations.nominal_w_values_dict
.- project
str
,optional
Name of the project with the design. The default is
"This Project*"
. However, you can supply the full path and name to another project.- force_source_to_solvebool,
optional
The default is
True
.- preserve_partner_solutionbool,
optional
The default is
True
.
- design
- Returns:
- bool
True
when successful,False
when failed.
References
>>> oModule.EditSetup
Examples
>>> m2d = ansys.aedt.core.Maxwell2d() >>> setup = m2d.get_setup("Setup1") >>> setup.start_continue_from_previous_setup(design="IM",solution="Setup1 : Transient")