create_fieldplot_line#
- PostProcessorIcepak.create_fieldplot_line(assignment, quantity, setup=None, intrinsics=None, plot_name=None, field_type='DC R/L Fields')#
Create a field plot of the line.
- Parameters:
- assignment
list
List of polylines to plot.
- quantity
str
Name of the quantity to plot.
- setup
str
,optional
Name of the setup. The default is
None
, in which case thenominal_adaptive
setup is used. Be sure to build a setup string in the form of"SetupName : SetupSweep"
, whereSetupSweep
is the sweep name to use in the export orLastAdaptive
.- intrinsics
dict
,str
,optional
Intrinsic variables required to compute the field before the export. These are typically: frequency, time and phase. It can be provided either as a dictionary or as a string. If it is a dictionary, keys depend on the solution type and can be expressed in lower or camel case as: -
"Freq"
or"Frequency"
. -"Time"
. -"Phase"
. If it is a string, it can either be"Freq"
or"Time"
depending on the solution type. The default isNone
in which case the intrinsics value is automatically computed based on the setup.- plot_name
str
,optional
Name of the field plot to create.
- field_type
str
,optional
Field type to plot. Valid only for Q3D Field plots.
- assignment
- Returns:
type
Plot object.
References
>>> oModule.CreateFieldPlot
Examples
>>> from ansys.aedt.core import Hfss >>> aedtapp = Hfss() >>> # Intrinsics is provided as a dictionary. >>> intrinsics = {"Freq": "5GHz", "Phase": "180deg"} >>> min_value = aedtapp.post.get_scalar_field_value(quantity_name, "Minimum", setup_name, intrinsics=intrinsics) >>> plot1 = aedtapp.post.create_fieldplot_line("Polyline1", quantity_name, setup_name, intrinsics=intrinsics) >>> # Intrinsics is provided as a string. Phase is automatically assigned to 0deg. >>> min_value = aedtapp.post.get_scalar_field_value(quantity_name, "Minimum", setup_name, intrinsics="5GHz") >>> plot1 = aedtapp.post.create_fieldplot_line("Polyline1", quantity_name, setup_name, intrinsics="5GHz") >>> # Intrinsics is provided as a dictionary. Phase is automatically assigned to 0deg. >>> intrinsics = {"Freq": "5GHz"} >>> min_value = aedtapp.post.get_scalar_field_value(quantity_name, "Minimum", setup_name, intrinsics=intrinsics) >>> plot1 = aedtapp.post.create_fieldplot_line("Polyline1", quantity_name, setup_name, intrinsics=intrinsics) >>> # Intrinsics is not provided and is computed from the setup. >>> min_value = aedtapp.post.get_scalar_field_value(quantity_name, "Minimum", setup_name) >>> plot1 = aedtapp.post.create_fieldplot_line("Polyline1", quantity_name, setup_name)