edit_design_settings#

Icepak.edit_design_settings(gravityDir=0, ambtemp=20, performvalidation=False, CheckLevel='None', defaultfluid='air', defaultsolid='Al-Extruded', export_monitor=False, export_directory='C:\\actions-runner\\_work\\pyaedt\\pyaedt')[source]#

Update the main settings of the design.

Parameters:
gravityDirint, optional

Gravity direction from -X to +Z. Options are 0 to 5. The default is 0.

ambtempfloat, str, optional

Ambient temperature. The default is 20. The default unit is celsius for float or string including unit definition is accepted, e.g. 325kel.

performvalidationbool, optional

Whether to perform validation. The default is False.

CheckLevelstr, optional

Level of check to perform during validation. The default is "None".

defaultfluidstr, optional

Default fluid material. The default is "air".

defaultsolidstr, optional

Default solid material. The default is "Al-Extruded".

export_monitorbool, optional

Whether to use the default export directory for monitor point data. The default value is False.

export_directorystr, optional

Default export directory for monitor point data. The default value is the current working directory.

Returns:
bool

True when successful, False when failed.

References

>>> oDesign.SetDesignSettings